Vážený zákazník, objednávky prijaté po 19.12.2024 budú vybavované od 7.1.2025. Prajeme príjemné prežitie vianočných sviatkov. Vážený zákazníku, objednávky přijaté po 19.12.2024 budou vyřizovány od 7.1.2025. Přejeme příjemné přežití vánočních svátků. Dear customer, orders received after December 19, 2024 will be handled from 7.1.2025. We wish you a Merry Christmas. Szanowny Kliencie, zamówienia złożone po 19.12.2024 będą realizowane od 7.1.2025. Życzymy Ci wesołych świąt.

2 NKV 15/7 T400/50 EN 12845 Automatic fire-fighting pressure station DAB.2 NKV EN 12845

Code: 60118537
Brand: IVAR
info

To view your purchase price you need to login, or register. The e-shop is for wholesale partners only..

The e-shop is for wholesale partners only.

Buy on atria.sk for 465,827Kč for end customer

Detailed information

Product detailed description

Automatic fire-fighting pressure stations are manufactured in accordance with the regulations of the European standard EN 12845.
European Standard EN 12845 specifies the design principles and conditions for the installation and maintenance of fire-fighting and sprinkler systems in buildings. It replaces the previous standards UNI 9489 and UNI 9490.
Automatic fire sprinkler systems are designed to detect the presence of a fire and extinguish it at an early stage, or to keep the fire under control until it can be extinguished by other means. A conventional fire sprinkler system includes: a water source, a fire automatic pressure station, a set of control valves, and a pressurized water distribution system with sprinklers.
The main pump triggered for fire fighting operates continuously until it is stopped manually by pressing the STOP button on the control panel. In the case of circuits with hydrants, reference is made to the UNI 10779 (July 07) standard which, in accordance with EN 12845, allows the main pump to be switched off automatically in certain circumstances.
Fire automatic pressure station. Under normal circumstances ( no water extraction) the system is maintained under static pressure. At even a small drop in pressure the auxiliary pump is started, its task is to restore the system pressure and thus eliminate small leaks. However, if the water flow is greater ( when the sprinklers are opened), the pressure is further reduced and the main pump is started. Starting of the main pump is done by disconnecting the external circuit with one of the two calibrated pressure switches in series. A pair of pressure switches starts the main pumps at the following pressure values: 4 to 29 m3 /h.

Additional parameters

Category: DAB.1 NKV, 2 NKV - fire stations EN 12845 with vertical pumps
Posledná aktuálizacia ceny: 25.11.2024 20:56:22