DAB.KE - pumps for pressure systems
CENTRIFUGAL PUMPS FOR PRESSURE SYSTEMS
DAB.KE
Centrifugal pumps with one or two impellers suitable for boosting pressure in domestic, civil, industrial and agricultural systems. Mainly thanks to the versatile use of the MCE/P converter, which guarantees automatic adjustment of the pump power for different system requirements, while maintaining a constant pressure. The pressure sensor is included in the delivery. The pump body and motor support are made of cast iron. Technopolymer impeller. Carbon/ceramic mechanical seal. Asynchronous motor cooled by external ventilation.
Centrifugal pumps KE with one impeller:
- Operating range: from 6 to 100 m3/h with a discharge of up to 60 meters
- Liquid temperature range: from -10 °C to +50 for KE 36/200 and KE 40/200 versions, from -15 °C to + 110 °C for other types of pumps
- Pumped liquid: clean, without solid or abrasive substances, which is non-viscous, non-aggressive, non-crystallizing and chemically neutral, properties close to water
- Installation: usually horizontal or vertical, provided the motor is always above the pump
- Maximum ambient temperature: +40 °C
- Maximum working pressure: KE 36/200, KE 40/200, KE 55/200: 8 bar (800 kPa), KE 40/400, KE 50/400, KE 30/800, KE 40/800, KE 50/800 , KE 20/1200, KE 25/1200, KE 35/1200: 10 bar (1000 kPa)
- Degree of protection of the motor: IP44
- Degree of protection of the terminal box: IP55
- Insulation class: F
KE centrifugal pumps with two impellers:
- Operating range: from 2 to 30 m3/h with a discharge of up to 95 meters
- Liquid temperature range: from -10 °C to +50 for versions KE 35/40, KE 45/50, KE 55/100, from -15 °C to + 110 °C for KE 55/50, KE 66/100, KE 90/100, KE 70/300, KE 80/300, KE 70/400, KE 80/400
- Pumped liquid: clean, without solid or abrasive substances, which is non-viscous, non-aggressive, non-crystallizing and chemically neutral, properties close to water
- Installation: usually horizontal or vertical, provided the motor is always above the pump
- Maximum ambient temperature: +40 °C
- Maximum working pressure: KE 35/40: 6 bar (600 kPa), KE 45/50, KE 55/50: 8 bar (800 kPa), KE 55/100, KE 66/100: 10 bar (1000 kPa), KE 90/100, KE 70/300, KE 80/300, KE 70/400, KE 80/400: 12 bar (1200 kPa)
- Degree of protection of the motor: IP44
- Degree of protection of the terminal box: IP55
- Insulation class: F